The Lightning Performance of High Voltage Transmission Line
8 Angebote vergleichen

Preise20142015201720182019
Schnitt 13,55 15,99 14,98 12,99 13,92
Nachfrage
Bester Preis: 12,67 (vom 16.03.2014)
1
9783656413530 - John Tarilanyo Afa: The Lightning Performance of High Voltage Transmission Line
Symbolbild
John Tarilanyo Afa

The Lightning Performance of High Voltage Transmission Line (2011)

Lieferung erfolgt aus/von: Vereinigte Staaten von Amerika DE PB NW

ISBN: 9783656413530 bzw. 3656413533, in Deutsch, GRIN Verlag, Taschenbuch, neu.

18,47 + Versand: 3,98 = 22,45
unverbindlich
Von Händler/Antiquariat, BuySomeBooks [52360437], Las Vegas, NV, U.S.A.
Paperback. 24 pages. Dimensions: 10.0in. x 7.0in. x 0.1in.Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, Atlantic International University (Niger Delta University), course: LPH 657, language: English, abstract: Lightning is a major source of danger to H. V transmission lines resulting in serious overvoltage which may cause flashover, puncture and sometimes loss of transmission line up to few hours or complete destruction of lines. The study is focused on Bayelsa State whose coastal areas occupy about eighty percent of the state. Due to its geographical location (Mangrove swamp forest) especially the coastal areas, these are areas of high thunderstorm and lightning days per year. This will pose significant influence on transmission line performance. From the present load with the proposed projects when completed may demand bulk power supply. The need of using high voltage transmission lines is there. Presently, it is expected that 132kv line may run from Yenagoa to Brass through Ogbia. It is therefore necessary to study the line performance in these areas of high Isokeraunic level. Lightning faults may be single or multi-phase and their elimination causes reclosing cycles, voltage dips and outages. Therefore the outage rate of a line and the quality of the delivered voltage depends on the lightning performance of the line. No transmission line design can be considered lightning proof, nor designers aimed at this goal. An acceptable design is to allow a certain number of outage per 100km of line or other line durations (Razevig 2003, Uglesic 2009). The probability of an outage depends on many factors which are statistical in nature that a worst case design is neither practical nor economical. This item ships from multiple locations. Your book may arrive from Roseburg,OR, La Vergne,TN.
2
9783656413530 - John Tarilanyo Afa: The Lightning Performance of High Voltage Transmission Line
John Tarilanyo Afa

The Lightning Performance of High Voltage Transmission Line (2013)

Lieferung erfolgt aus/von: Schweiz ~EN NW

ISBN: 9783656413530 bzw. 3656413533, vermutlich in Englisch, GRIN Publishing, neu.

18,13 (Fr. 19,90)¹ + Versand: 16,40 (Fr. 18,00)¹ = 34,53 (Fr. 37,90)¹
unverbindlich
Lieferung aus: Schweiz, Versandfertig innert 4 - 7 Werktagen.
The Lightning Performance of High Voltage Transmission Line, Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, Atlantic International University (Niger Delta University), course: LPH 657, language: English, abstract: Lightning is a major source of danger to H.V transmission lines resulting in serious overvoltage which may cause flashover, puncture and sometimes loss of transmission line up to few hours or complete destruction of lines. The study is focused on Bayelsa State whose coastal areas occupy about eighty percent of the state. Due to its geographical location (Mangrove swamp forest) especially the coastal areas, these are areas of high thunderstorm and lightning days per year. This will pose significant influence on transmission line performance. From the present load with the proposed projects when completed may demand bulk power supply. The need of using high voltage transmission lines is there. Presently, it is expected that 132kv line may run from Yenagoa to Brass through Ogbia. It is therefore necessary to study the line performance in these areas of high Isokeraunic level. Lightning faults may be single or multi-phase and their elimination causes reclosing cycles, voltage dips and outages. Therefore the outage rate of a line and the quality of the delivered voltage depends on the lightning performance of the line. No transmission line design can be considered lightning proof, nor designers aimed at this goal. An acceptable design is to allow a certain number of outage per 100km of line or other line durations (Razevig 2003, Uglesic 2009). The probability of an outage depends on many factors which are statistical in nature that a worst case design is neither practical nor economical. Geheftet, 22.04.2013.
3
9783656413530 - John Tarilanyo Afa: The Lightning Performance of High Voltage Transmission Line
John Tarilanyo Afa

The Lightning Performance of High Voltage Transmission Line (2013)

Lieferung erfolgt aus/von: Deutschland DE NW

ISBN: 9783656413530 bzw. 3656413533, in Deutsch, GRIN Publishing, neu.

Lieferung aus: Deutschland, Versandfertig in 2 - 3 Tagen.
The Lightning Performance of High Voltage Transmission Line Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, Atlantic International University (Niger Delta University), course: LPH 657, language: English, abstract: Lightning is a major source of danger to H.V transmission lines resulting in serious overvoltage which may cause flashover, puncture and sometimes loss of transmission line up to few hours or complete destruction of lines. The study is focused on Bayelsa State whose coastal areas occupy about eighty percent of the state. Due to its geographical location (Mangrove swamp forest) especially the coastal areas, these are areas of high thunderstorm and lightning days per year. This will pose significant influence on transmission line performance. From the present load with the proposed projects when completed may demand bulk power supply. The need of using high voltage transmission lines is there. Presently, it is expected that 132kv line may run from Yenagoa to Brass through Ogbia. It is therefore necessary to study the line performance in these areas of high Isokeraunic level. Lightning faults may be single or multi-phase and their elimination causes reclosing cycles, voltage dips and outages. Therefore the outage rate of a line and the quality of the delivered voltage depends on the lightning performance of the line. No transmission line design can be considered lightning proof, nor designers aimed at this goal. An acceptable design is to allow a certain number of outage per 100km of line or other line durations (Razevig 2003, Uglesic 2009). The probability of an outage depends on many factors which are statistical in nature that a worst case design is neither practical nor economical. 22.04.2013, Geheftet.
4
9783656413530 - Fremdsprachige Englische: The Lightning Performance of High Voltage Transmission Line
Fremdsprachige Englische

The Lightning Performance of High Voltage Transmission Line (2013)

Lieferung erfolgt aus/von: Schweiz DE NW

ISBN: 9783656413530 bzw. 3656413533, in Deutsch, GRIN Publishing, neu.

16,96 (Fr. 19,90)¹ + Versand: 15,34 (Fr. 18,00)¹ = 32,30 (Fr. 37,90)¹
unverbindlich
Lieferung aus: Schweiz, 22.04.2013.
The Lightning Performance of High Voltage Transmission Line, Technical Report from the year 2011 in the subject Engineering - Power Engineering, grade: A, Atlantic International University (Niger Delta University), course: LPH 657, language: English, abstract: Lightning is a major source of danger to H.V transmission lines resulting in serious overvoltage which may cause flashover, puncture and sometimes loss of transmission line up to few hours or complete destruction of lines. The study is focused on Bayelsa State whose coastal areas occupy about eighty percent of the state. Due to its geographical location (Mangrove swamp forest) especially the coastal areas, these are areas of high thunderstorm and lightning days per year. This will pose significant influence on transmission line performance. From the present load with the proposed projects when completed may demand bulk power supply. The need of using high voltage transmission lines is there. Presently, it is expected that 132kv line may run from Yenagoa to Brass through Ogbia. It is therefore necessary to study the line performance in these areas of high Isokeraunic level. Lightning faults may be single or multi-phase and their elimination causes reclosing cycles, voltage dips and outages. Therefore the outage rate of a line and the quality of the delivered voltage depends on the lightning performance of the line. No transmission line design can be considered lightning proof, nor designers aimed at this goal. An acceptable design is to allow a certain number of outage per 100km of line or other line durations (Razevig 2003, Uglesic 2009). The probability of an outage depends on many factors which are statistical in nature that a worst case design is neither practical nor economical.
5
9783656413530 - Afa, John Tarilanyo: The Lightning Performance of High Voltage Transmission Line
Symbolbild
Afa, John Tarilanyo

The Lightning Performance of High Voltage Transmission Line

Lieferung erfolgt aus/von: Vereinigte Staaten von Amerika DE PB NW

ISBN: 9783656413530 bzw. 3656413533, in Deutsch, Taschenbuch, neu.

16,30 + Versand: 3,53 = 19,83
unverbindlich
Von Händler/Antiquariat, BargainBookStores [1033621], Grand Rapids, MI, U.S.A.
This item is printed on demand. Item doesn't include CD/DVD.
6
3656413533 - John Tarilanyo Afa: The Lightning Performance of High Voltage Transmission Line
John Tarilanyo Afa

The Lightning Performance of High Voltage Transmission Line

Lieferung erfolgt aus/von: Deutschland ~EN HC NW

ISBN: 3656413533 bzw. 9783656413530, vermutlich in Englisch, GRIN Publishing, gebundenes Buch, neu.

12,99 + Versand: 7,50 = 20,49
unverbindlich
The Lightning Performance of High Voltage Transmission Line ab 12.99 € als sonstiges: 1. Auflage.. Aus dem Bereich: Bücher, Wissenschaft, Technik,.
7
3656413533 - The Lightning Performance of High Voltage Transmission Line

The Lightning Performance of High Voltage Transmission Line

Lieferung erfolgt aus/von: Deutschland ~EN NW

ISBN: 3656413533 bzw. 9783656413530, vermutlich in Englisch, neu.

The Lightning Performance of High Voltage Transmission Line ab 12.99 EURO 1. Auflage.
8
9783656413530 - Afa, John Tarilanyo: The Lightning Performance of High Voltage Transmission Line
Afa, John Tarilanyo

The Lightning Performance of High Voltage Transmission Line (2013)

Lieferung erfolgt aus/von: Deutschland ~EN NW

ISBN: 9783656413530 bzw. 3656413533, vermutlich in Englisch, neu.

Lieferung aus: Deutschland, Next Day, Versandkostenfrei.
Die Beschreibung dieses Angebotes ist von geringer Qualität oder in einer Fremdsprache. Trotzdem anzeigen
Lade…